Electrical Commissioning Lead

Lotusworks · Grafton, Wisconsin · Other

Posted 2026-10-03

Apply for this role →

LotusWorks is seeking an experienced Electrical Commissioning Lead to support the commissioning of critical electrical systems within a large-scale data center environment. This role will lead electrical commissioning activities from design review and equipment startup through functional performance testing, Integrated Systems Testing (IST), and final turnover. The position will focus on MV/LV switchgear, transformers, generators, UPS systems, ATS/STS, PDUs, busway, EPMS/SCADA, and related electrical distribution systems. The successful candidate will lead Cx engineers and technicians while coordinating with electrical contractors, NETA testing firms, controls integrators, OEM representatives, and the broader commissioning team to ensure systems are tested, issues are resolved, and the facility is ready for operations.

Responsibilities:

Planning & pre-construction

Review electrical design documents (one-lines, schedules, specs, protection/coordination study, arc flash study) for commission ability, testing access, and constructability

Develop the electrical section of the Cx Plan, including test sequencing, prerequisites, and Level 1–5 scope definitions

Write or review electrical Cx specifications and Division 26 Cx requirements

Define and track factory witness testing (FWT) requirements for switchgear, gens, UPS, PDUs, STS, ATS, busway

Coordinate with NETA-certified testing contractor scope; establish the boundary between NETA acceptance testing and Cx functional testing

Build the electrical Cx schedule and integrate it into the master schedule; identify long-lead test equipment (load banks, primary injection sets) and utility coordination milestones

Test script development

Author or approve Level 3 (start-up), Level 4 (functional performance), and Level 5 (IST) scripts for: MV/LV switchgear, transformers, generators and paralleling gear, ATS/STS, UPS and batteries, PDUs/RPPs, busway, lighting controls, grounding/bonding, EPMS/SCADA, fire alarm interface, and metering

Define pass/fail criteria tied to the Basis of Design and OPR (transfer times, voltage/frequency tolerances, battery runtime, protection settings)

Develop failure-mode and concurrent-maintainability test sequences (loss of utility, breaker failure, single-cord vs. dual-cord, load transfer cascades)

Field execution

Witness and document Level 2/3 installation verification, energization, and start-up

Direct Level 4 functional testing; verify protection settings match the coordination study; witness relay testing and primary/secondary injection

Lead electrical portions of Level 5 IST, including load bank testing, pull-the-plug tests, and utility-loss scenarios in coordination with the mechanical lead

Manage energization and LOTO coordination with the GC/EC safety program; enforce switching orders and approved MOPs

Verify EPMS/BMS point-to-point, alarm mapping, and trending before functional tests begin

Issues & documentation

Own the electrical issues log: log, classify (safety/critical/major/minor), track to closure, and verify corrective action via retest

Review and approve electrical Cx test reports, NETA reports, and vendor start-up reports for completeness and accuracy

Contribute the electrical sections of the Final Cx Report, including deferred/seasonal tests and outstanding items

Verify O&M manuals, as-builts, settings files (relay, UPS, gen controllers), and training are delivered before turnover

Coordination & leadership

Daily interface with the electrical contractor, factory service reps (gen, UPS, switchgear OEMs), NETA firm, controls integrator, and the mechanical Cx lead

Chair electrical Cx coordination meetings; report progress, readiness, and risk to the Cx Manager and owner

Supervise and QC the work of electrical Cx engineers/technicians assigned to the project

Escalate schedule, safety, or design conflicts early with recommended paths forward

Skills Required:

8–10+ years of experience in electrical construction, testing, or commissioning, with mission-critical/data center experience

Strong understanding of L1–L5 commissioning, including startup, functional performance testing, IST, and turnover

Working knowledge of NETA ATS, NFPA 70/70B/70E/110, IEEE 1584, and relevant utility standards

Ability to read and interpret one-line diagrams, control schematics, relay settings, and protection/coordination studies

Experience with MV/LV switchgear, transformers, generators, and paralleling gear

Experience with UPS, batteries, ATS/STS, PDUs/RPPs, busway, and electrical distribution systems

Familiarity with EPMS/SCADA, BMS interfaces, metering, alarm mapping, and electrical testing

ACG CxA, BCxA CCP, NETA Level III/IV, or AEE CxP certification preferred

Education / Licenses / Certifications

Relevant experience in electrical construction, testing, or commissioning will be considered in lieu of a specific degree

ACG CxA, BCxA CCP, NETA Level III/IV, or AEE CxP certification preferred

OSHA 30 required

Benefits:

Medical, Dental and Vision Insurance

Life, Short-Term, Long-Term Disability Insurance

Training and Education Assistance

401k Retirement Plan

Extra Annual Leave with Years of Service

Maternity/Paternity Leave

Recognition Rewards

Apply for this role →

← Back to all jobs